Kpe 123 kingstate как подключить
Перейти к содержимому

Kpe 123 kingstate как подключить

  • автор:

Kpe 123 kingstate как подключить

Номер в каталоге

Компоненты Описание

производитель

Unspecified

PIEZO INDICATOR

Model Number

Rated Frequency (Hz)

Operating Voltage Range (VDC)

Current Consumption (mA)

Max. 14@12VDC Max. 13@12VDC

Sound Pressure Level (dB) Min. 83dB@30cm@12VDC Min. 91dB@30cm@12VDC

Continuous

Operating Temperature ( ° C)

Storage Temperature ( ° C)

Weight (Gram)

ABS UL-94 1/16″ HB High Heat (Black)

Model Number

Rated Frequency (Hz)

Operating Voltage Range (VDC)

Current Consumption (mA)

Max. 15@12VDC Max. 13@12VDC

Sound Pressure Level (dB) Min. 88dB@30cm@12VDC Min. 91dB@30cm@12VDC

KPE-123 Datasheet PDF – Piezo Audio Transducer – Kingstage

1. Operating Frequency : 3.0 ± 0.5 KHz
2. Operating Volt. range : 3 ~ 28 VDC
3. Operating Current : MAX 8 mA
4. Sound pressure level : MIN 82 dB
5. Rated Voltage : 12 VDC
6. Weight (MAX) : 3.4 gram
7. Material : ABS UL-94 1/16″ HB High Heat (Black)
8. Operating Temperature : -30 ~ +85 ‘C
9. Storage Temperature : -40 ~ +95 ‘C

Other data sheets are available within the file: KPE123, KPE-132, KPE-133, KPE-134, KPE-161

PDF KPE-123 Data sheet ( Hoja de datos )

Hay una vista previa y un enlace de descarga de KPE-123 (archivo pdf) en la parte inferior de esta página.

KPE-123 Hoja de datos, Descripción, Manual

No Preview Available !

www.DataSheet4U.com

KPE-123 pdf

ww G w . .D E a N ta V Sh I e R e O t4U N .c M om ENT TEST
Test Condition
Evaluation standard
High temp. test After being placed in a chamber at + 95 for 240 hours
Low temp. test After being placed in a chamber with –40 for 240 hours
Humidity test After being placed in a chamber at +40 and 90±5% relative humidity
3 for 240 hours
Being placed for 4 hours at +25
, buzzer shall be measured.
The part shall be subjected to 5 cycles. One cycle shall be consist of:
The value of oscillation
frequency/ current consumption
should be in ±10% compared
+95 with initial ones .The SPL should
be in ±10dB compared with
initial one.
Temp. cycle test
0.5hr 0.5hr 0.25 0.5hr 0.5hr 0.5hr 0.25
H. RELIABILITY TEST
Test condition
Evaluation standard
Being placed for 4 hours at
+25 , buzzer shall be
measured. The value of
1.Continuous life test
oscillation frequency/ current
10 minutes continuous operation at +85 with maximum rated voltage applied. consumption should be in
2.Intermittent
A duty cycle of 1 minute on, 0.5 minutes off, a minimum of 960 times at room
temp.( +25 ±2 )and maximum rated voltage applied.
±10% compared with initial
ones .The SPL should be in
±10dB compared with initial
TEST CONDITION.
Standard Test Condition
Judgement Test Condition
: a) Temperature : +5 ~ +35ºC b) Humidity : 45-85% c) Pressure : 860-1060mbar
c) : 860-1060mbar
: a) Temperature : +25 ± 2ºC b) Humidity : 60-70% c) Pressure : 860-1060mbar
b) : 60-70% c) : 860-1060mbar
KINGSTATE ELECTRONICS CORP 5/6

Páginas Total 6 Páginas
PDF Descargar [ Datasheet KPE-123.PDF ]

Hoja de datos destacado

Número de pieza Descripción Fabricantes
KPE-123 Piezo Audio Transducer Kingstate

High Voltage 3 phase Motor Driver IC.

12- and 14-Bit Hybrid Synchro / Resolver-to-Digital Converters.

DataSheet.es es una pagina web que funciona como un repositorio de manuales o hoja de datos de muchos de los productos más populares,
permitiéndote verlos en linea o descargarlos en PDF.

DataSheet.es | 2020 | Privacy Policy | Contacto | Buscar

Добавить комментарий

Ваш адрес email не будет опубликован. Обязательные поля помечены *